lim-ts2 low intermodulation attenuators’ average power is 2w frequency range is dc-3ghz. it provides a test terminal for intermodulation test and the passive intermodulation of its own won’t affect the result of measuring. and the termination can be also used in high precision test and measuring in amplifier. |
|
|||||||||||||||||||||||||||||
|
rohs complient: yes |
|||||||||||||||||||||||||||||
electrical specifications |
||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||
note: xx refer to attenuation value in db, i, ii means 3rd order intermodulation value |
||||||||||||||||||||||||||||||
3rd order intermodulation |
typical test result: |
|||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||
note: custom designs available for 1800mhz, 2100mhz |
||||||||||||||||||||||||||||||
nominal impedance: 50ω average power: 2w average to 25°c ambient temperature, derated linearly to 0.5w @ 125°c
peak power: 0.5kw(5μs pulse width with 1% duty cycle)
connector type: n(j,k) |
lim-ts2 low intermodulation attenuators’ average power is 2w frequency range is dc-3ghz. it provides a test terminal for intermodulation test and the passive intermodulation of its own won’t affect the result of measuring. and the termination can be also used in high precision test and measuring in amplifier.
lim-ts5 low intermodulation attenuators’ average power is 2w frequency range is dc-3ghz. it provides a test terminal for intermodulation test and the passive intermodulation of its own won’t affect the result of measuring. and the termination can be also used in high precision test and measuring in amplifier.
lim-ts5 low intermodulation attenuators’ average power is 5w frequency range is dc-3ghz. it provides a test terminal for intermodulation test and the passive intermodulation of its own won’t affect the result of measuring. and it can be also used in high precision test and measuring in amplifier.
lim-dts50-a
low intermodulation attenuators’ average power is 50w frequency range is dc-3ghz. it provides a test terminal for intermodulation test and the passive intermodulation of its own won’t affect the result of measuring. under two 20w power intermodulation of dts-lim serial low intermodulation terminations less than -120dbc that make the test result reasonable. and the termination can be also used in high precision test and measuring in amplifier.
lim-dts100 low intermodulation attenuators’ average power is 100w frequency range is dc-3ghz. it provides a test terminal for intermodulation test and the passive intermodulation of its own won’t affect the result of measuring. under two 20w power, intermodulation of dts-lim serial low intermodulation terminations less than -120dbc that make the test result reasonable. and the termination can be also used in high precision test and measuring in amplifier.
low intermodulation attenuators can be used in situation of multiple port instruments transmission and reflect intermodulation measuring and the passive intermodulation of its own won’t affect the result of measuring. in two 20w power, intermodulation of dts-lim serial low intermodulation attenuators won’t over -150dbc that ensure to measure the intermodulation of the passive instrument exact. and this product also can be used in high precision test and measuring in amplifier.