low intermodulation attenuators can be used in situation of multiple port instruments transmission and reflect intermodulation measuring and the passive intermodulation of its own won’t affect the result of measuring. in two 20w power, intermodulation of dts-lim serial low intermodulation attenuators won’t over -150dbc that ensure to measure the intermodulation of the passive instrument exact. and this product also can be used in high precision test and measuring in amplifier.

mechanical specifications

connectors

ternary alloy

male pin

brass silver plated

female pin

beryllium copper silver plated

housing

aluminum

temp range

0° c ~ 45° c

dimensions

204×206×40mm

weight

3kg

 

rohs complient: yes

electrical specifications

model number

frequency

range(ghz)

attenuation value & accuracy (db)

max

vswr

10

20 30 40

dts100-xx-0830-n-lim

0.8-3

±1.2

±1.2 ±1.2 ±1.2

1.30

note: xx refer to attenuation value in db

3rd order intermodulation:

 

model number

two input  signals

reflection intermodulation

dts100-xx-0830-n-lim

935mhz & 960mhz

-150dbc@2×43dbm

 

note: custom designs available for 1800mhz,
2100mhz

 

nominal impedance50ω

average power100w

connector typen(j,k)

 

notes:

1. dimensions tolerance ±2%

 

related products

lim-ts2 low intermodulation attenuators’ average power is 2w frequency range is dc-3ghz. it provides a test terminal for intermodulation test and the passive intermodulation of its own won’t affect the result of measuring. and the termination can be also used in high precision test and measuring in amplifier.

lim-ts5 low intermodulation attenuators’ average power is 2w frequency range is dc-3ghz. it provides a test terminal for intermodulation test and the passive intermodulation of its own won’t affect the result of measuring. and the termination can be also used in high precision test and measuring in amplifier.

lim-ts5 low intermodulation attenuators’ average power is 5w frequency range is dc-3ghz. it provides a test terminal for intermodulation test and the passive intermodulation of its own won’t affect the result of measuring. and it can be also used in high precision test and measuring in amplifier.

lim-dts50-a low intermodulation attenuators’ average power is 50w frequency range is dc-3ghz. it provides a test terminal for intermodulation test and the passive intermodulation of its own won’t affect the result of measuring. under two 20w power intermodulation of dts-lim serial low intermodulation terminations less than -120dbc that make the test result reasonable. and the termination can be also used in high precision test and measuring in amplifier.

lim-dts100 low intermodulation attenuators’ average power is 100w frequency range is dc-3ghz. it provides a test terminal for intermodulation test and the passive intermodulation of its own won’t affect the result of measuring. under two 20w power, intermodulation of dts-lim serial low intermodulation terminations less than -120dbc that make the test result reasonable. and the termination can be also used in high precision test and measuring in amplifier.

      low intermodulation attenuators can be used in situation of multiple port instruments transmission and reflect intermodulation measuring and the passive intermodulation of its own won’t affect the result of measuring. in two 20w power, intermodulation of dts-lim serial low intermodulation attenuators won’t over -150dbc that ensure to measure the intermodulation of the passive instrument exact. and this product also can be used in high precision test and measuring in amplifier.